Application of High-Performance Capillary Electrophoresis to Quantification of Products of the Reverse Transcriptase-Polymerase Chain Reaction

https://ncu.repo.nii.ac.jp/records/70
https://ncu.repo.nii.ac.jp/records/70
d9eb353f-69b3-4479-b783-1aeea8c156b0
名前 / ファイル ライセンス アクション
B43-19970300-55.pdf B43-19970300-55.pdf (649.2 kB)
アイテムタイプ 紀要論文2 / Departmental Bulletin Paper(1)
公開日 2013-02-23
タイトル
タイトル Application of High-Performance Capillary Electrophoresis to Quantification of Products of the Reverse Transcriptase-Polymerase Chain Reaction
言語 en
言語
言語 eng
キーワード
言語 en
主題Scheme Other
主題 PCR
キーワード
言語 en
主題Scheme Other
主題 capillary electrophoresis
キーワード
言語 en
主題Scheme Other
主題 gliostatin
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ departmental bulletin paper
著者 Moriyama, Akihiko

× Moriyama, Akihiko

en Moriyama, Akihiko

Search repository
Matsukawa, Kohei

× Matsukawa, Kohei

en Matsukawa, Kohei

Search repository
Matsubara, Minako

× Matsubara, Minako

en Matsubara, Minako

Search repository
Kato, Taiji

× Kato, Taiji

en Kato, Taiji

Search repository
抄録(英)
内容記述タイプ Other
内容記述 To apply the high-performance capillary electrophoresis (HPCE) to the quantification of RT-PCR products, the conditions for the routine measurement were established as follows: the reaction mixture after RT-PCR (1 μl) was diluted 20-fold with deionized water and introduced into the capillary tube by electrokinetic injection at -10 kV for 40 sec. Electrophoresis was performed at -13 kV for 21 min. DNA was quantified spectrophotometrically at 260 nm during electrophoresis. This method was applied to the quantification of gliostatin mRNA in A 431 cells and compared to the amount of corresponding protein. The amount of gliostatin mRNA was well correlated with that of the protein (r = 0.733), when RT-PCR products derived from β-actin were used as internal standards. The data indicate that HPCE is useful to quantitate mRNA levels in cells.
書誌情報 en : Annual review

巻 1, p. 55-58, 発行日 1997-03
ISSN
収録物識別子タイプ ISSN
収録物識別子 13429329
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AA11168811
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 14:19:40.501755
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3